"Sincerity, Innovation, Rigorousness, and Efficiency" is definitely the persistent conception of our corporation to the long-term to establish alongside one another with customers for mutual reciprocity and mutual profit for foley catheter silicone , Suprapubic Catheter Unibal Balloon , pvc laryngeal mask factory , We sincerely hope to determine some satisfactory interactions with you in the in the vicinity of long term. We'll hold you informed of our progress and stay up for building steady small business relations along with you.
Renewable Design for 2 Way Balloon Urinary Catheter - Suprapubic Silicone Foley Catheter – Kangyuan Detail:

Suprapubic Silicone Foley Catheter Open Tipped with Integral Balloon Male Female
Made of 100% imported medical-garde silicone.
This product belongs to Class IIB.
Radio opaque line through the length fot x-ray visualization.
Soft and uniformly inflated balloon makes tube sit well against the bladder.
Special open-ended design, increase the volume of the drainage.
Color-coded check vavle for identification of different sizes.
Length of the Foley catheter: 400mm.

1

Packing: 10 pcs/box, 200 pcs/carton
Carton size: 52x35x25 cm

“KANGYUAN”Urinary Catheters for Single Use (Foley) is made of imported silicon rubber by advanced technology. The product has smooth surface, slight stimulation, large apocenosis volume, reliable balloon, convenient to use safely, multiple of types and specification for choice. 

This product is composed of urethral drainage catheter and temperature probe. Urethral drainage catheter consists of catheter body, balloon (water sac), guide head (tip), drainage lumen interface, filling lumen interface, temperature measuring lumen interface, flushing lumen interface (or no), flushing lumen plug (or no) and air valve. Temperature probe consists of temperature probe (thermal chip), plug interface and guide wire composition. Catheter for children(8Fr, 10Fr) can include a guide wire(optional). The catheter body, guide head (tip), balloon (water sac) and each lumen interface are made of silicone; the air valve is made of polycarbonate, ABS plastic and polypropylene; the flushing plug is made of PVC and polypropylene; the guide wire is made of PET plastic and temperature probe is made of PVC, fiber and metal material.

The product can be clinically used to urinate and douche urinary bladder by inserting into urinary bladder though urethra. 

1. Lubrication: Generously lubricate tip and shaft of the catheter before insert.

2. Insert: Carefully insert catheter tip into the bladder (normally indicated by urine flow), and then a further 3cm to ensure balloon is also inside it.

3. Inflating water: Using a syringe without needle, inflate balloon with sterile distilled water or 5%10% glycerin aqueous solution is supplied. Recommended volume to use is marked on funnel of catheter.

4. Extraction: For deflation , cut off the inflation funnel above the valve, or using a syringe without needle push into valve to facilitate drainage.

5. Dwell catheter: the dwelling time is as the requirement of clinic and nurse. 

The unsuitable condition considered by doctor. 

1. Do not use ointments or lubricants having a petroleum base.
2. Different specification of urethral catheter should be chose as different ages prior to use.
3. This product had been sterilized by ethylene oxide gas, and discard after single use.
4. If packing is damaged, do not use.
5. The size and balloon capacity is marked on outer unit pack and funnel of catheter.
6. The guide wire for the auxiliary intubation in the drainage channel of the catheter is pre placed in the children.
7. In use, such as the discovery of urinary catheter, urinary extravasation, inadequate drainage,
catheter replacement should be applicable specifications timely.
8. This product should be operated by medical staff.
9. Indwelling time recommend no more than 28 days.

[Warning]
The injection of sterile water shall not exceed the nominal capacity on the catheter (ml).

[Storage]
Store in a cool, dark and dry place, the temperature should not higher than 40℃, without corrosive gas and good ventilation.
[Date of manufacture] See inner packing label
[Expiry date] See inner packing label
[Registered person]
Manufacturer: HAIYAN KANGYUAN MEDICAL INSTRUMENT CO., LTD


Product detail pictures:

Renewable Design for 2 Way Balloon Urinary Catheter - Suprapubic Silicone Foley Catheter – Kangyuan detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization for that long-term to establish jointly with customers for mutual reciprocity and mutual gain for Renewable Design for 2 Way Balloon Urinary Catheter - Suprapubic Silicone Foley Catheter – Kangyuan, The product will supply to all over the world, such as: Serbia, Malaysia, New York, As an experienced group we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of our company is to build up a satisfactory memory to all customers, and establish a long term win-win business relationship. Choose us, we always wait for your appearance!
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Roberta from Turkey - 2018.07.26 16:51
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Myrna from Porto - 2018.10.31 10:02

    Related Products